CertaUPS C550R UPS system 6 - 10kVA by Power Control

Products

CertaUPS C550R 1

CertaUPS C550R

The CertaUPS C550R UPS system is an online double conversion uninterruptible power supply with unity power factor for tower or rack installation

Main applications include small data centres, server rooms, IT facilities, telecoms and networking

Product Features

  • Unity (1) output power factor
  • <600mm depth
  • 3 hours recharging to 90%
  • Online double conversion topology
  • Intelligent monitoring software
  • Server shut down in the event of a mains fail
  • High efficiency up to 98%
  • Smart LCD display
  • Expandable runtime
  • Parallel capacity for N 1
  • User replaceable, hot swappable batteries
WARRANTY3 Year Parts
RATING KVA6 / 10
DIMENSIONS (WxDxH)438W x 573D x 86.2H (UPS) 438W x 593D x 129H (battery) (C550R-060-B), 438W x 573D x 86.2H (C550R-060-C), 438W x 573D x 86.2H (UPS) 438W x 593D x 129H (battery) (C550R-100-B), 438W x 573D x 86.2H (C550R-100-C)
WEIGHT14 (C550R-060-B) / 16 (C550R-060-C) 14 (C550R-100-B) / 16 (C550R-100-C)
INPUT PHASESingle Phase
INPUT VOLTAGE220/230/240VAC
INPUT VOLTAGE TOLERANCE RANGE176-276VAC (100% load), 120-276VAC (50% load)
INPUT FREQUENCY50/60Hz
INPUT FREQUENCY TOLERANCE RANGE±10%
OUTPUT OUTPUT PHASESingle Phase
OUTPUT POWER FACTOR1
OUTPUT WAVEFORMSinewave
OUTPUT VOLTAGE208/220/230/240VAC
OUTPUT FREQUENCY50/60Hz (±10%)
OUTPUT EFFICIENCY>92% (Line mode - 6kVA), >93% (Line mode - 10kVA), >89% (Battery mode - 6kVA), >90% (Battery mode - 10kVA), >96% (Eco mode - 6kVA), >97% (Eco mode - 10kVA)
BATTERY RUNTIME5.5 minutes (C550R-060-B), Dependent on battery capacity (C500R-060-C), 3.5 minutes (C550R-100-B), Dependent on battery capacity (C500R-100-C)
BATTERY DC VOLTAGE180VDC (6kVA), 240VDC (10kVA)
BATTERY CHARGE CAPACITY1.4A (C550R-060-B) / 12A (C550R-060-C), 2A (C550R-100-B) / 12A (C550R-100-C)
MECHANICAL AC OUTLETSIEC C13*2, C19*1 and terminal block (C500R-060-B), IEC C13*2, C19*2 and terminal block (C500R-060-C) IEC C19*4 and terminal block (C500R-100-B), IEC C13*4, C19*2 and terminal block (C500R-100-C)
OPERATING TEMPERATURE TOLERANCE0 - 40°C
STORAGE TEMPERATURE TOLERANCE-15 - 40°C
RELATIVE HUMIDITY<95% (non-condensing)
OPERATING ALTITUDE TOLERANCE<3000m
COMMUNICATIONRS232 and USB
OPTIONAL COMMSSNMP / dry contact relays / Modbus
PARALLELUp to 3
FUNCTIONSEPO, Expandable Battery Modules, Rack/Tower Flexibility, Rotatable LCD, Dual Input

Document Download

    Make an Enquiry

    Please complete the form below.

    This page is protected by reCAPTCHA.
    Google Privacy Policy & Terms Apply.

    Power when you need it the most

    
    Seguidores Brasileiros
    X